LC 231
The LC 231 level controllers offer a comprehensive range of features for control and monitoring of pumps in wastewater, water supply and drainage systems.
The LC 231 pump controllers are designed for level control, monitoring and protection of Grundfos pumping systems one pumps or two pumps starting direct-on-line. The LC 231 pump controllers can be used in various type of empty application e.g. waste water transport, drainage or tank filling in water supply.
The set-up of the control is easily done either by the predefined application settings or via the step-by-step start-up wizard in the intuitive Grundfos GO app, using Bluetooth Smart technology. With the Grundfos GO app, all detailed pump settings can be easily being configured, monitored and commissioned. Even without using the app, you have the option directly from display to change the operation mode from auto to manual start/stop and adjusting the level setting.
The controller is equipped with configurable input/output terminals, giving full flexibility for all applications. Daily control, supervision and commissioning is straightforward with the intuitive and easy- to-use user interface. This saves you valuable time when getting started, and in your daily interaction with pumps and the controller.
The controller integrates seamlessly into the Grundfos range of communication modules, ensuring an easy fit into any supervisory system such as SCADA or Grundfos CLOUD.
With the built-in certified motor protection, and the current measurement, the LC 231 pump controller provide a service indicator function hat helps keep track of when service is needed.
The controller maintains a detailed alarm and warning log with the last 20 alerts. The alarm log can be accessed remotely via SCADA or Grundfos CLOUD. You can also use Grundfos GO to inspect the logs in localized, translated text for easy troubleshooting and remedial measures at the pumping station.
The LC 231 controller enable:
Alarm indication of:
As standard, the LC 231 controller has two alarm relays that can be configured using Grundfos GO to show a variety of status information on a supervisory system or PLC.
Regeling:Stroommeting (Ja/Nee): Y
Technisch:Goedkeuringen: CE,EAC,UKCA,MOROCCO,RCMAantal pompen: 1
Materialen:Kast: Plastiek
Installatie:Bereik van omgevingstemperatuur: -25 .. 45 °CKastmontage: MuurmontageAarding: N, PE
Elektrische gegevens:Netfrequentie: 50 / 60 HzNominale spanning 2e waarde: 1 x 110-240 V [3 x 200-460 V]Nominale stroom: 1-12 AGrootte bedrijfscondensator: N/A µFGrootte startcondensator: N/A µFAanloopmethode: Direct-on-line (DOL)Dichtheidsklasse (IEC 34-5): IP54Back-up zekering vereist: 16 ARequired Cos phi full load: 0.86-1.00
Overige:Netto gewicht: 1.78 kgBruto gewicht: 2.56 kgTransportvolume: 0.015 m³Danish VVS No.: 391378571Swedish RSK No.: 5886183Finnish LVI No.: 4965397Norwegian NRF no.: 9910003Land van herkomst: THHS code: 85371098
The LC 231 level controllers offer a comprehensive range of features for control and monitoring of pumps in wastewater, water supply and drainage systems.
The LC 231 pump controllers are designed for level control, monitoring and protection of Grundfos pumping systems one pumps or two pumps starting direct-on-line. The LC 231 pump controllers can be used in various type of empty application e.g. waste water transport, drainage or tank filling in water supply.
The set-up of the control is easily done either by the predefined application settings or via the step-by-step start-up wizard in the intuitive Grundfos GO app, using Bluetooth Smart technology. With the Grundfos GO app, all detailed pump settings can be easily being configured, monitored and commissioned. Even without using the app, you have the option directly from display to change the operation mode from auto to manual start/stop and adjusting the level setting.
The controller is equipped with configurable input/output terminals, giving full flexibility for all applications. Daily control, supervision and commissioning is straightforward with the intuitive and easy- to-use user interface. This saves you valuable time when getting started, and in your daily interaction with pumps and the controller.
The controller integrates seamlessly into the Grundfos range of communication modules, ensuring an easy fit into any supervisory system such as SCADA or Grundfos CLOUD.
With the built-in certified motor protection, and the current measurement, the LC 231 pump controller provide a service indicator function hat helps keep track of when service is needed.
The controller maintains a detailed alarm and warning log with the last 20 alerts. The alarm log can be accessed remotely via SCADA or Grundfos CLOUD. You can also use Grundfos GO to inspect the logs in localized, translated text for easy troubleshooting and remedial measures at the pumping station.
The LC 231 controller enable:
- Control of 1 or 2 pumps based on signals from sensor input (analog, 0-5 V, 0.5-3.5V, 0-10 V, 0-20 mA, 4-20 mA or digital, float switch)
- Support up to five control levels for both analogue level transmitter or float switch operation
- Supports simple application where only one float switch is present - single float switch operation.
- Configurable input/output terminals that can be used as digital input/output, analogue input and Pt 100/1000 inputs for flexible use in the actual application
- Prevent the pumps with anti-seizing from choking or seizing due to limestone build-up or other deposits
- Prevent the mains load when several pumping stations are started up at the same time with power-on delay.
- Protection against water hammer as quick restart/simultaneous start is blocked and delayed
- Selection of automatic alarm resetting
- Setting of stop delays matching the actual operating conditions
- Shows the actual liquid level
- Alarm indication via a build in buzzer
Alarm indication of:
- Power/current overload
- Dry running
- High water level
- Incorrect phase sequences or missing phase
- Sensor inconsistency or failure
- Intrusion detection
- Water on floor
- Too many restarts
- Pump overheating and moisture detection
As standard, the LC 231 controller has two alarm relays that can be configured using Grundfos GO to show a variety of status information on a supervisory system or PLC.
Regeling:Stroommeting (Ja/Nee): Y
Technisch:Goedkeuringen: CE,EAC,UKCA,MOROCCO,RCMAantal pompen: 1
Materialen:Kast: Plastiek
Installatie:Bereik van omgevingstemperatuur: -25 .. 45 °CKastmontage: MuurmontageAarding: N, PE
Elektrische gegevens:Netfrequentie: 50 / 60 HzNominale spanning 2e waarde: 1 x 110-240 V [3 x 200-460 V]Nominale stroom: 1-12 AGrootte bedrijfscondensator: N/A µFGrootte startcondensator: N/A µFAanloopmethode: Direct-on-line (DOL)Dichtheidsklasse (IEC 34-5): IP54Back-up zekering vereist: 16 ARequired Cos phi full load: 0.86-1.00
Overige:Netto gewicht: 1.78 kgBruto gewicht: 2.56 kgTransportvolume: 0.015 m³Danish VVS No.: 391378571Swedish RSK No.: 5886183Finnish LVI No.: 4965397Norwegian NRF no.: 9910003Land van herkomst: THHS code: 85371098
Numéro de l'annonce: m2146739967
Mots-clés populaires
voyance in Diverslecteur in Diversarrimage in Diverstatouage in Diversenlèvement ferraille in Diversouija in Diversbernard in Diversepave in Diverspiles in Diverswestern in Diversmachine a cigarette in Diversrecherche personne in Diversminiatuur 1 | 12 dans DiversDiverscaddie dans Diverstable bistrot jardinanna kathleen amantnaaimachine zigzagvaes in Antiquités & Artvloerisolatie